    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
Home > Products >
UV Germicidal Disinfection Lamp
UV rays with a wavelength of 254nm are easily absorbed by organisms and act on the genetic material DNA of the organism, causing the DNA to be destroyed and causing the death of bacteria. UV rays can ...
  • UV rays with a wavelength of 254nm are easily absorbed by organisms and act on the genetic material
    DNA of the organism, causing the DNA to be destroyed and causing the death of bacteria.
    UV rays can concentratehigh intensity to kill bacteria and viruses in a short time.
    UV sterilization is a pure physical disinfection method without secondary pollution.UV rays can
    kill various bacteria and viruses, including COVID-19, H1N1,higella-dysentery, Aspergillus flavus,protozoa,
    E. coli, infectious hepatitis, influenza, yeast (bacteria), etc.



    Widely use
    uv lamp can be used in many places.Like bedroom, hospitals, hotels, restaurants, offices, factories,
    public toilets, airports.etc

    Safe to Use
    This UV germicidal light has 360 degree Radar device, can automatically cut-off the power when sense
    Living-thing move, and start working again after 15 seconds no sense any move. Avoid UV light to hurt people.
    The UV disinfection light has a 5-8 meter remote controller, even can control lights through the wall.
    It also has 3 gear timing (15/30/60 minutes) function and 15s delay timing, You could adjust different time
    to disinfection to meet your need.

    Professional Disinfection
    High-purity quartz glass tube means it's more durable, PVC flame-resistant material and open heat dissipation
    to a long life, not easy to age, safe insulation. 254 NM wavelength, 36 Watt. The UV and ozone emitted by
    the uv lamp will bring you double protection, high-power design to strengthen the disinfection capacity,
    360 ° wide beam angle,sterilization rate of 99%.



    Matters needing attention:
    1 UV rays are harmful to human or animal skin and eyes. Please do not look directly or
       be exposed to UV rays.

    2 When disinfecting the surface of articles with UV light, the irradiated surface should be
       directly irradiated with UV rays,and sufficient irradiation dose should be achieved.

    3 During use, the surface of the UV lamp should be kept clean. After use, it should be placed
       in a dustproof box after cooling.
  • Characteristics of Guta UVC germicidal disinfection lamp:

    1 Wide working voltage 110 / 220VAC, suitable for all countries.

    2 36W high power design, stronger sterilization power.

    3 UV lamp with high quality quartz shell.

    4 3pcs infrared human sensors are evenly panoramic distributed
       to prevent people or pets from being exposed to UV radiation.

    5 Flexible setting of UV light radiation time, 15/30/60 minutes adjustable.

    6 The buzzer sounds can help outside person to know the UVC lamp status: start , stop or pause by
       some human being or pets.


  • Model No. GT-GL1901UVC
    Output Lamp power 36W
    Light source UV quarz H-tube UVC lamp ,wave length:254nm
    Alarm sound (TYPE) 70db
    Input Working voltage 110-240VAC
    Working current(TYPE) 0.18A@220V
    Working frequency 50Hz/±5%  60Hz/±5%
    Power factor ≥92%/220V
    Efficiency ≥88%/220V
    Standby power cost <1W
    Inrush current Cold start:≤25A
    Protection Infrared human sensor sensitive distance About 3m
    Human approach Turn off the UVC lamp
    Start Delay 15 seconds
    Function Timer 15/30/60 minutes settable
    Start delay 15 seconds
    UV radiation time Digital display
    Start buzzer Bi (one time)
    Stop buzzer Bi-Bi (twice)
    Human approach Constant 30 seconds
    Environment Working temperature -10℃~+50℃
    Storage temperature and humidity -20℃~+65℃,10-95%RH
    Safety Standards IEC60335-1,IEC60335-2-65,EN61347-1,EN61347-2-3
    Compressive strength Input to the outer casing:AC2500V/2mA/60S
    Insulation resistance ≥100MΩ
    Protection level IP20
    Others Product size φ120*460mm
    Package size (L*W*H) 143*143*482mm
    Weight(kg) Net :   Cross:
    Certificates CE, Intertek CTL, Rohs