    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
Conventional Fire Alarm Contro...
Home > Products > Conventional Fire Alarm Control System LPCB Approved
Standalone Wifi Smoke Detector AW-D611W
The Standalone Wifi Smoke Detector detector is a photo-detector that uses the most advanced optical sensing chamber.It is designed to provide open area protection without wiring, and it is easy to ins...
  • The Standalone Wifi Smoke Detector detector is a photo-detector that uses the most advanced optical sensing chamber.It is designed to provide open area protection without wiring, and it is easy to install and construct. 
    When a fire alarm occurs, the indicator light will continue to light up, the buzzer will sound for a long time and the alarm data will continue to be sent to the cloud via Wifi, and the cloud will issue an APP alarm until the APP terminal is reset. When the battery is at a low voltage, the indicator light will flash, the buzzer will beep, and the data will be sent to the cloud via Wifi once and will be sent to the APP.The test button, indicator light, and buzzer can be used together for different tests and settings
     
     
     
    The red indicator light on the detector can provide a full range of visibility alarm. Flashes once every minute, indicating that the detector is working.
     
    Standalone Wifi Smoke Detector detector characteristics
    Surface mounting
    Loud sound warning
    LED indicator
    No wire connection(easy to install)
    Automatic alarm for low battery voltage
    Compatible with the latest EN-14604 standards
     
    Standalone Wifi Smoke Detector detector Routine operation:
    1) Button test: Under normal circumstances, click the button, the buzzer will beep once, and the LED will flash 2 times, indicating that the device is operating normally. 
     
    2) Silence: Click the button under the fire alarm to silence the sound for 5 minutes, counting from the first silence, and it is not allowed to continue silence after 15 minutes. 
     
    3) Fire alarm reset: press and hold the button for 3 seconds under fire alarm to reset
     
    Wifi operation instructions:
    1) Wi-Fi is powered on for the first time, initialized, wait for 3-5 seconds, wait for the module to return to Wi-Fi status, and perform related operations according to Wi-Fi status:
     
    A. Intelligent distribution network, AP distribution network mode: it means that the module has not been equipped
    with a network after the previous reset, and a new network is needed. Keep the network status, and the indicator light keeps flashing fast or slowly. 
     
    B. The network is configured, but not connected to wifi or connected to wifi, but not connected to the cloud: Wait for wifi to connect to the cloud, if it is still not connected after 20s, Dididi will report a fault for 1 minute and then enter sleep, at least keep it on Electricity can be connected to the router for the first time
     
    C. connected to the cloud: report the status once, then turn off the wifi and enter sleep.
    Wireless test: Under normal circumstances, long press the button for 3 seconds to activate wireless and report dataonce. 
    Wireless network configuration (or reset to re-configure network, or switch network configuration mode): When the network is not configured, long press for 3 seconds to enter the network configuration mode, and long press again for 3 seconds to switch to the network configuration mode; if the network is configured, long press 10 Seconds reset.