    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
Detector Test Equipment
Home > Products > Detector Test Equipment
Inregrated Two In One Smoke Temperature Tester
Integrated two-in-one smoke temperature tester is a fire detectorintegrating smoke detection and temperature detection. It can carry out a simulated test on the smoke detector and temperature detector...
  • Product function overview
    smoke-type(all types of ion, photoelectric and complex smoke detector) fire detector and 
    temperature-type fire detector(fixed-temperature type, rate-of-rise type, rate-of-rise and 
    fixed temperature type). 
    Maintenance, test, commissioning, acceptance and agility test can be carried on 
    It applies to the fire safety inspection, fire safety detection, fire safety maintenance, and 
    fire safety engineering and so on.
    Integrated two-in-one smoke temperature tester is a fire detector integrating smoke 
    detection and temperature detection. It can carry out a simulated test on the smoke 
    detector and temperature detector.
     
    Electric atomizing and fuming technology is specially adopted for fuming. The 
    specially-designed environmental-friendly liquid for vaporization is free from soot and 
    tobacco tar and will not cause secondary pollution on the detector.
     
    Fuming technology passed the fire safety department testing and certification and 
    environmental protection testing and certification.
     
    Electric energy conversion technology is adopted to rapidly raise the temperature to the 
    alarm threshold of temperature detector within a short time.

    Precautions:
    .If the product contains combustible gases, it should be placed in shady places 
    below ℃.
    .The first charging of battery rod (relay device to be purchased separately) 
    should not be fewer than  hours.
    .As the body of the gun is made of stainless steel, it should be distanced from 
    the electrified body in use.
    .As the head of the gun is made of anodizing aviation aluminum, it should be 
    distanced from the electrified body in use.
    .Devices idle for a long time should be charged once a month.
    .Test temperature detector. Normally, a small amount of smoke will be 
    released form the public output port of smoke detection.
    .During the smoke detector test, the test time is suggested to be - seconds 
    and alarm can be issued after the end of routine inspection of hosts.
    .ml-ml liquid for vaporization is injected before usage.

  • Type of test
    Smoke detector
    Temperature Detector
     
    Material
    Aluminum alloy box
    Detector material stainless steel
     
    Standard length
    .m. If you need to lengthen, you can buy a connecting rod.
     
  • Product parameters
    Battery voltage: DC.V, MA/H
    Charger output: DC.V, MA
    Oil chamber capacity: ML
    Number of smoke detectors to be tested when the battery is fully charged: -
     
    Number of heat detectors to be tested when the battery is fully charged: >
    Smoke source: environmental-friendly liquid for vaporization
    Temperature source: electronic heating
    The total length of the tester: .m
    Materials of the connecting rod: stainless steel.
    Materials of package box: aluminum