    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
Linear Heat Detection System
Home > Products > Linear Heat Detection System
Digital Type linear Heat Detectors
Compared with other kinds of detectors. MS1000 Digital Linear Heat Detector provides a very-early alarm detecting function to the protected environment, The detector can be known as an intelligent "sw...
  • 1.Compared with other kinds of detectors. MS1000 Digital Linear Heat Detector provides a very-early alarm detecting function to the protected environment, The detector can be known as an intelligent "switch" type detector. The polymers between the two conductors will break down at specific fixed temperature allowing the conductors contact, the shot circuit will initiate the alarm. The detector has a continuous sensitivity. The sensitivity of linear heat detector will not be influenced by the environment temperature changing and the length of detection cable using. It does not need to be adjusted and compensation. The detector can transfer both alarm and fault signals to control panels normally with DC24V or without DC24V.
    Linear Heat Detection Cable Classification
    Conventional Type:This type of Linear heat detection cable is the most widely indoor used with strong stability.
    CR/OD Type:CR/OD Type not only has good UV resistance and good weather resistance, strongly recommended for outdoor using even under bad weather conditions, but also with high performance of acid resistant, alkali-resistant, salt spray resistant.
    EP Type:Explosion Proof Type. Two main application environments: harsh EMI environment and explosive hazardous environment. The outer jacket of this type is protected by woven metal mesh with good performance of anti-EMI and eliminating the surface static of the Linear heat detection cable. We can use this type Linear heat detection cable in explosive hazardous environment with safety fence. During the installation, please make grounding connection of the woven metal mesh. Used in harsh EMI environment, single end grounding connection or double ends grounding connection should be specified after analysis of the interference sources.

    2.Structure
    Intertwisting two rigid metallic conductors which are covered by NTC heat sensitive material, with insulative bandage and outer jacket, here comes the Digital Type Linear Hear Detection Cable . And the different model numbers depend on the variety of materials of outer jacket to meet different special environments.


  • Features and benefits
    • Industrial safety design
    • Electrical interface with low power consumption design .Real-time monitoring
    • Working with DC24V supply or without DC24V supply
    • Fast response time
    • No alarm temperature compensation needed
    • Compatible to any kind fire alarm system
    • Plenty levels of alarm temperatures:from 68C to 180C
  • Operating Voltage: DC 24V
    Allowed Voltage Range: 16VDC-28VDC
    Standby Current: < 20mA
    Alarm Current: < 30mA
    Fault Current: < 25mA
    Maximum Relative Humidity for Long Term Use: 90%-98% . IP Rating: IP66
    Alarm temperatures: 68°C, 88°C, 105°C, 138°C & 180