Since 2005, Fire Alarm System And Fire Suppression System Manufacturer&Whole Solution Provider
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
Conventional Fire Alarm Contro...
Home > Products > Conventional Fire Alarm Control System LPCB Approved
Conventional Manual Call Point AW-D135C
The conventional manual call point is a fire alarm device operated by humans. When activated, it can send fire signal to the fire panel. This passage will introduce the features, installation, wiring ...
  • The AW-D135C Conventional manual call point is designed to be use with an intelligent two-wire control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the equipment status of the manual fire call points. When the manual fire call points is operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit.
     
    This passage will introduce the features, installation, wiring and use of AW-D135C conventional manual call point, to help you understand more about the conventional manual call point.
     

    How To Install Conventional Manual Call Point 

    The AW-D135C conventional manual call point can be semi-recessed or mounted on the wall surface. When installing, this manual call point has to be installed in the order of base, middle cover, and top cover. Fix the base on the wall, then attach the middle cover to the base, and finally attach the top cover to the middle cover.
     
    The size of the base is 87mm×7mm×33mm (L×W×H), the mounting hole diameter is φ5mm, and the fixed hole spacing is 36mm.
     

    How To used Conventional Manual Call Point 

    1.Activation
    When a fire occurs, press the button in the middle of the manual call point, then the manual call point will send a fire signal to the fire panel, and the LED indicator will be on.
     
    2.Reset
    After the manual call point is done using, it is necessary to reset it with the reset key, so that the conventional manual call point can be in a normal state again and get ready for the next use.
    How To used Conventional Manual Call Point

    How to Wire Conventional Manual Call Point
     
  • 1.Conventional Manual Call Point Appearance
    The AW-D135C conventional manual call point is made of ABS, weights about 95g, and its color is red. 
     
    2.LED Indicator
    The AW-D135C conventional manual call point has a LED indicator. When the manual call point is under the normal state, the indicator will flash regularly. When the manual call point is under alarm state, the indicator will remain on.
     
    3.Conventional Manual Call Point Working Environment
    The AW-D135C conventional manual call point is better to work under the temperature range of -10 to 55°C, and the environment’s relative humidity is better to be less than 95% (non-condensing).
     
    4.Application
    This conventional manual call point is suitable for indoor use, in order to better achieve product performance.
     
    5.Executive Standard
    This conventional manual call point complies with the EN54-11 standard. With excellent reliability and high stability, this manual call point is safe and easy to use.

     

  • Model AW-D135C
    Main Voltage Zone 24V or 12V
    Operating current monitoring status≤20uA, alarm status≤15mA
    Application For indoor use only
    Wiring The promise of two bus system(Zone +, Zone -)
    Indicator Red alarm indicator flashes when it is under normal condition, 
    press the manual button lit work
    Protection class IP30
    Environmental Class A temperature range: -5 to 40°C (23~104°F) 
    Humidity: 5 to 95% RH, non-condensing
    Materials and colors ABS, red
    Mating Panel AW-CFP2166 fire alarm control panel
    Size 99mm* 92mm* 66mm(with cover)
    Weight about 95g