    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
CO2 fire suppression system
Home > Products > CO2 fire suppression system
CO2 fire Suppression System
CO2 Extinguishing System automatic extinguishing system consists of bottle group bracket, storage bottle of extinguishing agent, container valve, high-pressure hose, check valve, header pipe, safe...
  • CO2 Extinguishing System automatic extinguishing system consists of bottle group
    bracket, storage bottle of extinguishing agent, container valve, high-pressure hose, check
    valve, header pipe, safety valve, distribution pipe, selector valve, pressure signal device,
    transmission pipeline of extinguishing agent, decompression device, nozzle, start-up
    bottle, actuator, start-up pipeline and start-up gas check valve etc. CO2 Extinguishing
    System automatic extinguishing system is a kind of intelligent automatic extinguishing
    system. In accordance with requirements for use in different places for application, the
    unit independent system and combined distribution system can be constituted and the
    way of total flooding extinguishing can be used in order to realize the extinguishing
    protection of single protection area and multi-protection area. CO2 Extinguishing System
    automatic extinguishing system has advanced technology and high extinguishing
    efficiency and can be maintained easily. This system has 3 start-up modes including
    automatic operation, manual operation and mechanical emergency operation.
     
  • This system is mainly applicable to fires as follows:
    1) Gas fire in the event that gas source can be cut off before extinguishment;
    2) Liquid fire or fire due to fusible solids such as paraffin and asphalt;
    3) Fire on solid surface and deep-seated fire of partial solids such as cotton, fabric,
    and paper ;
    4) Electrical fire;
    Typical referenced places:
    The CO2 extinguishing system is mainly applicable to the fire protection of key places
    such as electronic computer room, data storage room, library, bank vaults, storehouse of
    valuables, storehouse of paper, storehouse of cotton, storehouse of food, storehouse of
    Chinese herbal medicine, storehouse of fur and cable tunnel. The system can also be
    used in the production operation places with fire dangers such as dipping tank, melting
    tank, roller mill, textile machine, generator, printing press, oil immersed transformer, oil
    switch, high-rating generator, hydraulic equipment, drying equipment, patent equipment,
    dust-removing equipment, cooking utensils, paint discharge production line, electric aging
    room, pulverized coal bunker in cement production process and ship cabin and cargo
    space.
  • Model & Specifications of Product
    QME(Volume of Storage Bottle of Extinguishing 
    Agent)-PAVLN
    Volume of Storage Bottle of 
    Extinguishing Agent (L)
    70/80L
    Storage Pressure of Extinguishing 
    Agent
    5.7MPa(20℃)
    Maximum Working Pressure
    12.4MPa(50℃)
    Filling Density of Extinguishing 
    Agent
    ≤0.60 kg/L
    Working Start-up Power
    DC24V,1.5A
    Technical Ways of 
    Extinguishment
    Total Flooding
    Discharge Time of Extinguishing 
    Agent
    ≤ 60 S
    Start-up Mode
    Automatic, Manual and Mechanical Emergency 
    Operation
    Driving Gas
    Nitrogen
    Ambient Temperature for Use
    0 ℃ ~ 50 ℃
    Filling Pressure of Start-up Gas
    6MPa(20℃)