Since 2005, 16 Years Fire Alarm System Suppression and Manufacturer&Whole Solution Designer
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    ASENWARE Conventional Fire Alarm System has obtained lpcb ce certificationconsists, The system has Conventional Fire Alarm Control Panel, Smoke Detector ,Heat Detector , Beam Smoke Detector,Entrance LED Indicator etc composed
    ASENWARE Addressable Fire Alarm Control System are intelligent system which are designed to make it suitable for most of applications. It’s user friendly functionality makes it suitable to program and configure the devices. 7 ” touchscreen display gives the information for fire alarm, trouble , supervisory and other related information all the time.This system fully complied with the requirement of EN 54-2 and EN 54-4.
    ASENWARE Wireless fire alarm system features: Can connect both wired and wireless detectors Each zone can connect up to 20 wireless detectors and 20 wired detectors
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE fire fighting telephone system is the special communication equipment for fire fighting
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical RFQ
2100/2189 series Addressble Fi...
Home > Products > 2100/2189 series Addressble Fire Alarm System
AW-ASS2188 Addressable Hooter/Horn
AW-ASS2188 Addressable Hooter/Horn is a mated product of the 2100 series fire alarm control panels.
  • The AW-ASS2188 addressable hooter/horn(hooter/horn for short) is a kind of product manufactured by our company to be used with bus-type fire alarm control units. 

    Controlled by amicroprocessor, the hooter/horn can realize real-time communication with a bus-type fire alarm control unit and receive the control commands sent by it. When in a routing inspection, the red status indicator will blink; after anaccident happens, the hooter/horn will start to operate after receiving a startup command from the bus-type fire alarm control unit. 
     

    The red status indicator will remain lit and the hooter/horn will give a flashing signal and an audible alarm signal to notify the persons on the scene of the accident that a fire has occurred on the site and of the necessity to take related evacuation measures, thus preventing the fire accident from becoming amajor one. The hooter/horn may be restored to the monitoring status after the MUTE or RESET key on the bus -type fire alarm control unit is pressed. The hooter/horn may be used to give audible alarms and flashing alarms on the scenes of accidents.

    It is suitable for places like high-rise residential buildings, public places, hotels, amusement buildings, factories, shopping centers, hospitals, schools, office buildings and stock exchanges, particularly places with low visibility or the possibility of generation of smoke. 

  • Features:
    1. It can realize complete electronic coding and in situ rewriting with the help of a coder.
    2. The audible alarm and flashing alarm may be set freely. In other words, the hooter/horn may give an audible alarm and a flashing alarm at the same time or separately and it can be adapted to different working environments.
    3. Designed with an upper cover and a lower cover, it can be installed, debugged and maintained conveniently.
    4. It uses multiple super bright red LEDs as light sources for visual display, ensuring a striking display, a longer service life and low power consumption.
     
  • Parameters: 
    1. Operating voltage: 24V (pulse modulation);
    2. Operating current: quiescent current: ≤1mA (the current consumed by the bus); alarm current: ≤120mA@DC24V;
    3. Flushing rate: one time/s;
    4. Operating environment: Indoor, temperature: -10℃~+55℃; relative humidity: ≤95% (40℃±2℃, without condensation);
    5. Alarm volume: >85dB (measured at a place 3m in front of the hooter/horn);
    6. Coding method: Electronic coding;
    7. Wiring method: Four-wire system, non-polarity two signal buses (L1, L2) and power lines (+24V, GND);
    8. Matched host machine: fire alarm control panel (such as AW-AFP2188, AW-AFP2100).