    ASENWARE Conventional Fire Alarm System has obtained lpcb ce certificationconsists, The system has Conventional Fire Alarm Control Panel, Smoke Detector ,Heat Detector , Beam Smoke Detector,Entrance LED Indicator etc composed
    ASENWARE Addressable Fire Alarm Control System are intelligent system which are designed to make it suitable for most of applications. It’s user friendly functionality makes it suitable to program and configure the devices. 7 ” touchscreen display gives the information for fire alarm, trouble , supervisory and other related information all the time.This system fully complied with the requirement of EN 54-2 and EN 54-4.
    ASENWARE Wireless fire alarm system features: Can connect both wired and wireless detectors Each zone can connect up to 20 wireless detectors and 20 wired detectors
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE fire fighting telephone system is the special communication equipment for fire fighting
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical RFQ
2100/2189 series Addressble Fi...
Home > Products > 2100/2189 series Addressble Fire Alarm System
AW-AMC2188 Addressable Manual call point
AW-AMC2188 Addressable Manual call point is a mated product of the 2100 series fire alarm control panels.
  • The AW -AMC2188 addressable manual call point (manual call point for short) is mainly designed to be used with an intelligent two-bus control panel. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control panel which will, after receiving the alarm signal, display the coded address and the equipment status of the manual call point.

    When the manual call point is operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit. The manual call point supports electronic coding and has a built-in fire telephone jack and a PHONE indicator, making its engineering application convenient.


  • Features:
    1. It can realize complete electronic coding and in situ rewriting with help of a coder.
    2. Designed with an upper cover and a lower cover, it can be installed, debugged and maintained conveniently.
    3. It is designed with a two-wire fire telephone jack and is therefore more applicable to engineering application.
    4. Designed with passive output contacts, it can control other external equipment directly through an intermediate relay.
    5. The pressing sheet on the manual call point will not get crushed after it is pressed, but can be reset by a special tool, so it can be used repeatedly.
     
  • Parameters: 
    1. Operating voltage: 24V (pulse modulation);
    2. Operating current: <300uA (in the monitoring status); <2mA (in the action status);
    3. Output contact: Normally open contact; capacity: 0.1A/30VDC;
    4. Weight: About 120g;
    5. Wiring method: nonpolar two-bus system (L1, L2);
    6. Operating environment: Indoor, temperature: -10℃~+50℃; relative humidity: ≤95% (40℃±2℃, without condensation);
    7. Coding method: It can realize online coding with the help of a coder and without the necessity of disassembling the bus (however, the equipment must be powered off). Address codes 1 to 324 are available for selection;
    8. Telephone jack: Two-wire fire telephone jack (equipped with a standard  Ф6.3 single-track audio connector);
    9. Starting part: A plastic pressing sheet that may be used repeatedly. It can be manually reset with a special tool after being pressed;
    10. Starting mode: Press the pressing sheet manually;
    11. Indicator: The red ALARM indicator will blink in the inspection status or remain lit in the alarm status; the PHONE indicator will blink when a fire telephone loop is connected, otherwise it will be out;
    12. Matched host machine: fire alarm control panel (such as AW-AFP2188, AW-AFP2100).