Since 2005, 16 Years Fire Alarm System Suppression and Manufacturer&Whole Solution Designer
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    ASENWARE Conventional Fire Alarm System has obtained lpcb ce certificationconsists, The system has Conventional Fire Alarm Control Panel, Smoke Detector ,Heat Detector , Beam Smoke Detector,Entrance LED Indicator etc composed
    ASENWARE Addressable Fire Alarm Control System are intelligent system which are designed to make it suitable for most of applications. It’s user friendly functionality makes it suitable to program and configure the devices. 7 ” touchscreen display gives the information for fire alarm, trouble , supervisory and other related information all the time.This system fully complied with the requirement of EN 54-2 and EN 54-4.
    ASENWARE Wireless fire alarm system features: Can connect both wired and wireless detectors Each zone can connect up to 20 wireless detectors and 20 wired detectors
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE fire fighting telephone system is the special communication equipment for fire fighting
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical RFQ
2100/2189 series Addressble Fi...
Home > Products > 2100/2189 series Addressble Fire Alarm System
AW-AIS2188 Addressable Isolator Module
AW-AIS2188 Addressable Isolator Module is a mated product of the 2188/2100 series fire alarm control panels.
  • AW-AIS2188 short circuit isolators are used for the short circuit fault protection of buses. When a bus circuit is operating normally, the AW-AIS2188 short circuit isolator will not operate; when a short circuit fault occurs at a place at the output end of the short circuit isolator in the bus circuit (short-circuit current >200mA), the section suffering the short circuit fault will be cut off from the bus, thus ensuring the normal communication of the other sections of the bus. Upon elimination of the short circuit fault, the short circuit isolator can automatically bring the isolated section into the system again.


  • Features:
    1. A short circuit isolator will make it convenient to confirm the location suffering a short circuit fault.
    2. The short circuit isolator does not need coding nor occupies the address in the bus circuit.
  • Parameters: 

    1. Mode of operation: Nonpolar two-wire system;
    2. Quiescent current: <5.0mA;
    3. Operative current: >200mA;
    4. Operation indicator: Red (It is out in the normal monitoring status or remains lit in the operation status);
    5. Operating environment: Temperature: -10℃~50℃; relative humidity: ≤95% (40℃±2℃, without condensation);
    6. External dimensions: 86×86×40mm (with the base);
    7. Weight: about 125g (with the base).