    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
Newsroom
Home > Newsroom
How to Choose Gas Suppression System
2022-11-01
There are some common gas suppression systems, like FM-200 gas suppression system and CO₂ gas suppression system, etc. FM-200 gas suppression system can be divided into hanging type gas suppression system, cabinet type gas suppression system and manifold type gas suppression system.
 
When choosing the gas suppression system, which type should you choose? This article will analyze different types of gas suppression systems to help you in the selection.
 

FM-200 Gas Suppression System

Among these gas suppression systems, the FM-200 gas suppression system can be divided into several types: the hanging type gas suppression system, the cabinet type gas suppression system and the manifold type gas suppression system.
manifold type gas suppression systemcabinet type gas suppression systemhanging type gas suppression system
 
When choosing the FM-200 gas suppression system, you can refer to the following regulations:
Regulations on the number of equipment when installing FM-200 gas suppression systems in the protected area
1.When an FM-200 gas suppression system is used for two or more protected areas, it should not cover more than 8 protected areas.
2.There should be no more than 10 devices of FM-200 gas suppression system installed in a protected area.
3.When there is more than one gas suppression system device in one protected area, they can be started together if necessary, but the time difference between the actions of the devices should not be longer than 2 seconds.
 
Regulations for the area and volume of the places FM-200 gas suppression system is installed
1.The protected area should be divided into single enclosed spaces. When the ceiling and under-floor in the same section need to be protected together, they can be combined into one protected area.
2.When using a networking gas suppression system, its protecting area should not be larger than 800m², and the volume should not be larger than 3600m³.
3.When using a pre-engineered gas suppression system, its protecting area should not be larger than 500m², and the volume should not be larger than 1600m³.

How to design FM200 gas suppression system



How To Install Hanging Type FM200 Gas Suppression System

It shows that the cabinet type gas suppression system and the hanging type gas suppression system are suitable for the protected area with a small volume.
 

CO₂ Gas Suppression System

CO₂ Gas Suppression System

When choosing the CO₂ gas suppression system, you can refer to the following regulations:
When the gas suppression system protects 5 or more protected areas or protection objects, or when the gas suppression system can’t be restored within 48 hours, there should be a reserve amount of CO₂, and the reserve amount should not be less than the storage amount planned by the system. For the high-pressure system and the low-pressure system with a separate reserve storage container, the reserve storage container should be connected to the system pipeline network and should be able to switch with the main storage container.
 

How To Install CO2 Fire Suppression System And How Does It Work

 

It shows that the networking gas suppression system is suitable for a large number of protected areas and the protected area with a large volume.