Voice Evacuation System
AW-EVC100 Emergency Voice Evacuation Controller User Manual
AW-EVC100 emergency voice evacuation controller is suitable for communication and dispatch in case of fire or emergency in the building.
Product overview
AW-EVC100 emergency voice evacuation controller is suitable for communication and dispatch in case of fire or emergency in the building. When a fire occurs in the application scene, the emergency evacuation audio will be played, and the on-site personnel can make a speaker call through the controller microphone to schedule the on-site evacuation.
Product Features
There is an emergence evacuation button that can be manually operated to activate the fire alarm, displaying with alarm information in editable language
Equipped with EMC Microphone which issued to evacuate people When it is in emergency situation
3.2-inch LCD screen and silicon buttons for visual operation
Provided with various source input including 2 AUX and 2 MIC
Supports playback of audio in MP3, WAV format with USB flash disk and Bluetooth
There are 20 zones of fire detection input, which are activated one by one with the 20 zones of speaker zones when the fire alarm is triggered, and when the fire disappears it will automatically recover.
Each broadcast zone needs to connect to constant voltage loudspeaker with 2, 3 wire connection
Autonomously control the opening and closing of the broadcast zone
There are 120 fire zones that can be linked to the broadcast zone via CAN in the Fire Alarm Control Panel ( like FP128, FP200 ). If the linkage is preseted in the EVC100, the evacuation audio will be played when EVC100 receive the fire signal from he Fire Alarm Control Panel.
Each broadcast zone can be set with an individual timer to delay playing the evacuation audio when received fire signal
Support a maximum of 60 broadcast zones by connecting to EV603
2 loops of paging input interfaces, which can connect two paging devices, and can broadcast notification and audio through Paging at a long distance.
Support AC power supply and 24V battery power supply, can automatically identify and switch, AC power supply priority
1 monitoring speaker, which can monitor the audio of the input audio source
Built-in SD card, used to store emergency alarm audio files ( MP3, WAV format)
Technical parameters
Technical Parameters
Rated input voltage ~ 100V-260V, 50/60Hz
Maximum current T3.15A
Working environment Relative humidity (<95%) at -20 ~40 ℃, no condensation)
Standby Audio Output Balance 1V,<0.3% 1KHz
MIC1/MIC2 input sensitivity and frequency response   Balance,10mV/80Hz~10KHz±3DB
MIC1-2 input SNR >70dB
AUX1-2 input sensitivity and frequency response   Unbalance,350mV/20Hz~20KHz±3DB
AUX1-2 Input SNR >90dB
Paging Input Frequency response 20HZ-20KHZ±3DB
Alarm Input 20 channel
Paging Distance >=600m(with CAT-5E OFC cable)
Remote MIC communication CAN bus
Slave Controller Communication RS485 bus
Battery Input Voltage and Current 24V DC±20%/3A