Addressable Fire Alarm Control System LPCB Approved
LPCB Addressable Fire Alarm Strobe Sounder Beacon AW-D306 for fire alarm system
AW-D306 Addressable Sounder Beacon can give audible and visual alarms after being connected to a DC24V power supply and a bus loop. It can be used with a bus-type fire alarm control panel. After receiving a start command given by the fire alarm control pa
Product overview
AW-D306 Addressable Sounder Beacon can give audible and visual alarms after being connected to a DC24V power supply and a bus loop. It can be used with a bus-type fire alarm control panel. After receiving a start command given by the fire alarm control panel following an accident, the Sounder Beacon will begin to work. At this moment, the Sounder Beacon will give a dazzling visual alarm signal and a harsh audible alarm signal ,to remind the persons on the scene of the accident , the fact that a fire has occurred on the site ,quickly and necessity to take related evacuation measures, thus preventing the fire accident from becoming a major one.
The Sounder Beacon may be used to give audible alarms and visual alarms at the scenes of accidents.It is applicable to places like high-rise residential buildings, public places, hotels, amusement buildings, factories, shopping centers, hospitals, schools, office buildings and stock exchanges, and particularly to the places with a low visibility or the possibility of generation of smoke.
 

How To Wire Addressable Sounder Beacon

Product Features

Strobe Sounder Beacon features:

1. Meet both EN54-3 and EN54-23.
2. Designed with an upper cover and a lower cover and installed on an independent base, it can be installed,debugged and maintained conveniently.
3. Suitable for wall and ceiling mount application.
4. Providing 16 tones.
5. Highly efficient LED technology
Technical parameters

Strobe Sounder Beacon Technical parameters:


Loop input DC24V(18-28V),≤1mA(monitoring status),≤3mA(alarm status)
Power input DC24V(20-28V),≤4mA(monitoring status),≤130mA(alarm status)
Power consumption ≤3.2W@DC24V
EN54-23 Coverage C-3-8/W-2.4-6(coverage volume see the following figures)
Flash Color and
Frequency
White, 0.5Hz
Light Output
Synchronization
Meets EN54-23
Sound Level See the following table”Sound Level Data”
Ingress Protection
Rating
IP21C
Operating Temperature -10℃ ~ +50℃
Relative Humidity ≤95%, non condensing
Material of Lens/Body Flame retardant PC/ABS
Dimension ф100mm×100.5mm( with the base)
Mounting Hole Spacing 45mm ~ 70mm
Weight About 270g (with the base)
Loop input DC24V(18-28V),≤1mA(monitoring status),≤3mA(alarm status)