Asenware FM-200 Fire extinguishing system
	 
	Asenware FM-200 Fire extinguishing system are designed for total flooding
	to protect high value assets and normally occupied area where it is not suitable
	to use CO2 or other harmful extinguishing agent. Main features for FM- 200
	extinguishment are :
	
		 
	
		• Colorless and non-toxic gas, suitable for normally occupied area, where there
		is any chance of presence of human present, it is dangerous to use CO2. FM-200
		is a hydrocarbon chemical agent, which contains no toxic compound and it does
		not produce any harmful compound after reacting with any product of combustion.
	
		
			 
		
			• Perfectly suited to protect high value assets areas like telecommunication room,
			control rooms etc. These area are sully occupied and contains a high assents, water
			is not suitable to use as it may damage the electrical equipment and even a little fire
			can shut down the facility and damage the business. FM-200 is one of the best solution
			which extinguish the fire through chemical reaction and cooling effect and leaves no
			residue after extinguishment.
		
			
				 
			
				• Electrically non-conductive and contains no particle or residue, which makes it
				suitable for using in electrical and control rooms.
			
				
					 
				
					• Suitable for Class A , Class B and Class C fire. Asenware FM-200 System extinguish
					the fire which are categorized in Class A , B and C.
				
					
						 
					
						• Extinguish fires rapidly : As discharge time is less than 10 second, it mixes in the
						environment and make free radical to react with fire products and extinguish fire quickly.
					
						
							 
						
							Asenware FM-200 Extinguishing System has two types of system.
							 
						
							
								Pre Engineered and engineered system.
								 
							
								1. Pre-Engineered or Cabinet System : It is a total flooding system, and it is designed
								based on pre-determined maximum volume of hazard. and It can be easily move and
								adjusted at any location in the hazard area.
							
								
									 
								
									2. Engineered System or Manifold System : In manifold system, a suitable size of
									manifold which is calculated based on the agent and volume, all tanks are connected
									to manifold and then through piping distribution agent is discharged through nozzles
									in the specific area.
								
									
										 
									
										Using selector valves, multiple hazard areas can be protected using a single
										cylinder bank.
									
										
											
											MODES OF OPERATION
											 
										
											There are three modes of operation as listed below
										
											• Automatic Operation
										
											• Remote Manual Operation
										
											
												• Local Manual Operation
												
												1. Automatic Operation
												 
											
												When the control panel operate the solenoid valve upon receiving signal from detectors,
												solenoid will actuate the cartridge after certain delay time ( if given ) and gas will discharge
												into the hazard area.
											
												
													 
												
													* With Asenware Gas Release Control Panel : Normally, the panel remains in ‘Auto’ position.
													Upon receiving the signal from detectors , panel immediately released pre-discharge alarm
													and turn off the HVAC or dampers if any. And then release the gas after pre-determined
													delay period.
												
													
														
														2. Remote Manual Operation
														 
													
														When the operation is performed by remote pull station, an appropriate pull station is
														operated after detecting fire in the specific hazard area.
													
														
															 
														
															With Asenware Gas Release Control Panel : Asenware Gas Release panel additionally
														
															provide manual operation from panel , one must put the key to ‘manual’ position. After
															pushing the manual release located on the panel, gas will be released as operation
															described above.
														
															
																
																* All instruction for operation must be inscribed nearby pull station.
																
																3. Local Manual Operation
																 
															
																In case of failure of automatic actuation, Asenware FM-200 system has the provision
																to operate it manually. In this scenario, one must proceed to appropriate FM-200
																cylinders arrangements for specific hazard area. Remove the safety pull pin from the
																pilot cylinder as instructed on the nameplate. And pull the lever and gas will release
																immediately.
																
																