Since 2005, Fire Alarm and Suppression System Manufacturer & Whole Solution Designer,
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 24 standard. 
    Asenware FP300 series is a LPCB addressable fire alarm system with one loop of 324 addressable points, comply with EN 54 standard.
    Smoke Detector is a device that senses smoke, typically as an indicator of fire.
    ASENWARE Heat Detector is photo-electronic detector using a state-of-the-art optical sensing chamber. 
    ASENWARE Smoke and Heat Detector is photo-electronic detector using a state-of-the-art optical sensing chamber. 
    Voice Evacuation Control Panel and Speakers
    Fire Telephone is a new fire special communications equipment when the fire accident.
    ASENWARE units are designed for the purpose of alerting audio and visual awareness to an emergency situation.
    Conventional Manual Call Point is designed for conventional fire alarm system to report fire in emergency condition 
    Fire Bell is the fire alarm, a fire alarm device, generally used for more staff in public areas
    ASENWARE Reflex Beam Smoke Fire Detector, being designed for fire prevention, is a long interval one and used with the fire alarm controller
    ASENWARE Flame Detector provides a new generation of flame detection capability and technical standards
    Fire Proof Cable is used where critical circuits need to function to keep safety equipment running even when exposed to extreme heat or fire. 
    AW-AFP2189 is a new type of analog fire alarm control panel which has 324 alarm control points 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.
    ASENWARE FM200 (Heptafluoropropane, HFC-227ea) fire extinguishing system is a gas fire, automatic control and fire detection.
    ASENWARE Explosion-Proof Series is a indispensable equipment in explosion-proof fire alarm system.
    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Other Fire Alarm Accessories
  • Project
  • Newsroom
  • Company
  • Contact
LPCB Addressable Fire Alarm Sy...
Home > Products > LPCB Addressable Fire Alarm System
LPCB Addressable Fire Alarm System Heat Detector AW-D302
AW-D302 Addressable Heat Detector (Detector hereunder) is a mated product of the AW-FP300 fire alarm control panel. It uses a two-bus work mode. With an internal microprocessor, it supports electronic...
  • AW-D302 Addressable Heat Detector (Detector hereunder) is a mated product of the AW-FP300 fire alarm control panel. It uses a two-bus work mode. With an internal microprocessor, it supports electronic coding. The detector realizes real-time acquisition of the in situ temperature data and sends back the data to a fire alarm control panel. It can also receive and execute the control commands given by a fire alarm control panel. When in a routing inspection, the detector indicator will blink. When there is a fire in the monitored area and the temperature has reached the alarm threshold, the fire alarm control panel will confirm a fire alarm according to the received message sent from the detector, and the detector indicator will light at the same time to indicate a fire alarm.
    The detector is suitable for such industrial and civil buildings that have a great deal of heat when fire takes place, such as kitchens, boiler rooms, generator rooms, drying workshops and smoking rooms and is not suitable for places with a great deal of smoke but little heat.
  • 1) It can realize electronic coding and rewrite the address via coder in situ.
    2) Within a single-chip microcomputer, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation.
    3) It has a temperature compensation function and a sensor fault detection function (fault reporting to fire alarm control panel).
    4) Non-polarity, two-bus connection that ensures convenient installation and maintenance.
    5)Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
    6)Built-in remote indicator output terminal, drive remote indicator lit when fire alarm