Since 2005, Fire Alarm System And Fire Suppression System Manufacturer&Whole Solution Provider
We supply whole fire alarm and suppression system include conventional fire alarm system, addressable fire alarm system, emergency light system, FM200 gas suppression system, fire pump, fire hose reel and cabinet.
  • Home
  • Products
    Fire alarm system plays an important part of the fire and life safety of building and its occupants. Fire alarm system main function is to detect a fire at a sufficiently early stage so that the people who are at risk can made safely either by escaping as fast as possible or extinguishing the fire that can also reduce or prevent the property damage. Therefore, a reliability and functionality of fire alarm system as a whole is very important. 

    The following are the different types of the Fire Alarm System:

    1. Conventional fire alarm system

    a. Conventional fire alarm system uses physical cabling to connect several detectors and call points. Conventional fire alarm system has no way to identify immediately the exact location of the fire, but can be arranged in “Zones” to easily identify the location of the cause of the alarm. Its devices are cheaper but will consume more cable wires compare to addressable, since each device will be connected to the control panel by its own cable wire. This system are mainly used specially in smaller property.
    conventional fire alarm system Wiring diagram 

    2. Addressable fire alarm system

    a. Addressable fire alarm system has the same detection principle, except that each detector can be given a set address that can help to identify the exact location of the detector that initiated the alarm, that can be seen in the fire alarm control panel. Addressable fire alarm system saves a lot of wire compare to conventional system, since the devices can share one cable wires up to the last device. Both ends of the wire is loop connected to the fire alarm control panel. This system are very suitable for large and high buildings, since they are able to pinpoint exactly which devices are triggering the alarm.
    addressable fire alarm system Wiring diagram

    3. Wireless fire alarm system

    a. Wireless fire alarm system, is hassle-free to install compare to conventional and addressable since it does not use any conduit and cable wires. However, even though you saved a lot of money in material and labor cost, the hardware and programming are higher than the wired systems. The devices are battery powered and can be placed anywhere and can be easily relocate if needed.
    wireless fire alarm system

    Fire Alarm System Components 

    The main component of fire alarm system are the following:
    1. Fire Alarm Control Panel
    Fire Alarm Control Panel is the brain or central hub of a fire alarm system. It displays the location and status of the alarm devices, and it gives precise location of the device that cause the alarm.
    fire alarm control panel
    2. Fire Alarm Initiating Devices
    Fire Alarm Initiating Devices are the devices that detects signs of fire and triggers the alarm. They are connected to the fire alarm system control panel. Initiating devices includes smoke detectors, heat detectors, flame detectors, manual pull station and fire sprinkler water flow switch.
    Fire Alarm Initiating Devices
    3. Fire Notification Devices
    Fire Notification Devices are the audible and visual devices in fire alarm system, it includes fire alarm horn, speaker and bell. Its main function is to alert people at risk in the event of a fire, that is why it is considered as the most important components of fire alarm system.
    Fire Notification Devices
    4. Primary Power Supply
    Primary power supply is typically supplied by the local utility, and also from generators that are located in remote areas wherein the electrical grid is not available. 
    5. Backup Power Supply
    Backup power supply commonly supplied by batteries and stored internally or adjacent to main fire alarm control panel or can be also from generator. It must also provide a 24 hours of power supply to control panel in case of power shortage.

    How Fire Alarm System Works? 

    In an event of a fire emergency, the fire alarm system main role is to detect fire and to alert people at risk inside the building and emergency response team to control the situation as fast as possible. Fire alarm system key functions is to detect (by the use of smoke detectors, heat detectors, flame detectors, etc.) , alert (by the use alarm horn, speaker, and bell), and monitor (control panel). 

    Fire Alarm System Maintenance 

    A functioning and well-maintained fire alarm devices can help reduce injuries, save lives and properties. The fire safety systems inspection, routine maintenance, and testing will help one in keeping in compliance with the local/state fire inspectors and also their insurance carrier. To keep the best condition of the fire alarm devices, it is advisable to keep a scheduled maintenance and check the following: 
    1. Checking of physical appearance of the fire alarm devices
    2. Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type)
    3. Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function
    4. Checking of the devices power supply
    5. Checking/ replacement of batteries
    6. Checking/ removal of any obstruction on the devices that may cause false alarm or malfunctioning
    7. Checking if the alarm is audible
    8. Devices must be replaced when exceeded 10 years from the manufactured date

     

    ASENWARE Centralized Monitoring Emergency Luminaire System is designed for managing, monitoring and controlling emergency lights automatically. 
    ASENWARE Fire Pump Series provide fire departments or private users with the ability to pump from any water source.

    At ASENWARE, you can choose the best quality of fire fighting equipment like  extinguisher, hose reels, fire monitors, nozzles and hose pipes.
  • Project
  • Newsroom
  • About Us
  • Contact
  • Technical FAQ
2100/2189 series Addressble Fi...
Home > Products > 2100/2189 series Addressble Fire Alarm System
AW-AFP2100 Addressable Fire Alarm Control Panel
  • The AW-AFP2100 series control panel (linkage type) (fire alarm control panel) is a new generation product launched by ASENWARE. In order to adapt to the needs of engineering design, the fire alarm control panel is designed with a linkage control function that enables it to be flexibly used with other related products from ASENWARE to form a fire alarm and linkage integrated control system. It is particularly suitable for applications in large and medium-sized fire alarm and linkage integrated control systems.

    The AW-AFP2100 series addressable control panel is a dual wire analog bus system. It can replace the conventional fire alarm system to save 50% or more cables.

    The AW-AFP2100 series addressable control panel is an advanced, perfect and reliable system, which is designed for big porjects, has been used in many countries.

  • Characteristics:
     
    1. New generation high-speed microprocessor technology;
    2. Operating interfaces simulate the menus and interfaces of Windows;
    3. Non-polarity two-bus intelligent alarm linkage mode adoption;
    4. Controllable standard PS/2 computer keyboard and mouse as on-site programming devices;
    5. Each detector sensitivity adjustable;
    6. 7.4'LCD back-light display;
    7. Windows menu and inteface;
    8. English interface and panel display;
    9. CF card duplicate or reset system setup file and history file to facilitate maintenance;
    10. single point test of detector/module;
    11. Zone, building or floor integration and display;
    12. Graphic monitor system visually display the location of fire and trouble;
    13. Eleven users each with a password and selectable access levels;
    14. Field software upgrade;
    15. 20 AW-AFP2100 peer-to-peer, long-distance optical fiber transmission network via CAN communication transform module;
    16. Flexible collocation by modularized combination.
  • Parameter: 

    Capacity:
    1. Each loop card has 2 loops, with 324 addresses as alarm/control points of each loop, the capacity of each loop card is 324*2=648(addresses);
    2. Each wall mounted AW-AFP2100 panel can be installed maximum 3 loop cards, the maxium capacity is 648*3=1944(addresses). Over 1944 addresses, use the cabinet panel, the cabinet panel can be installed maxium 40 loop cards, the maximum capacity is 648*40=25920(addresses);
    3. Peer-to-peer with max.20 AW-AFP2100 panels, the maxium system capacity: 25920*20=518400(addresses);
    Maximum simultaneous alarm of each host:
    • Fire alarm: 500;
    • Trouble: 500;
    • Feedback: 500.
    Operating evironment:
    Temperature  -10℃~+55℃
    Humidity ≤95%, 40℃,non-condensing
    AC Power  AC220V, 50HZ,3A
    DC Power  DC24V,7A